MANOMETRO DE DIAFRAGMA ESTANDAR

alt
APLICACION MODELO TECNOLOGIA MARCA
Presión PF100,D4/ 160,D4/ 100Gly,D8/ 160Gly,D8 Neumática AFRISO
FUNCION CODIGO SECCION
Manómetro de Diafragma Estandar 01-1038 01

Standard diaphragm pressure gauges.

Application.

For non-corrosive gaseous and liquid media. With open connecting flange also suitable for viscous and polluted media. When measuring gas or vapour, the instruments must be used in accordance with the safety recommendations of EN 837-2.

Type D 4
Nominal size 100 – 160
Accuracy class (EN 837-3/6) 1.6
Ranges (EN 837-3/5) 0/10 to 0/250 mbar (flange Ø 160) 0/0.4 to 0/25 bar (flange Ø 100)

.

alt


Application area
Static load: full scale value
Dynamic load: 0.9 x full scale value
Overpressure safety 1.3 x full scale value over 0.6 bar overpressure safety 5 x FSD, however, 40 bar max.

Operating temperature range
Medium: Tmax = +100 °C
Ambient: Tmin = -20 °C
Tmax = +60 °C

Temperature performance
Indication error when the temperature of the measuring element deviates from 20 °C: rising temp. approx. ±0.8 %/10 K falling temp. approx. ±0.8 %/10 K percentage of full scale value

Protection IP 54 (EN 60529)



Standard version

Connection
Steel, bottom G1/2B – spanner size 22 (EN 837-3/7.3)
Lower flange Steel
Upper flange Stainless steel
Measuring element Diaphragm, Measuring flange Ø 100: up to 1.6 bar Duratherm, over 2.5 steel Measuring flange Ø 160: Stainless steel 316 Ti or 316 L Sealing gasket to pressurised area "Perbunan" nitrile rubber
Movement Brass
Dial Aluminium, white Dial marking black
Pointer Aluminium, black
Housing Stainless steel 304 with blow-out
Bayonet type bezel Stainless steel 304
Front glass Instrument glass

Options

  • Safety housing
  • Overpressure safety 10 x FSD flange Ø 100 up to 40 bar max., flange Ø 160 up to 2.5 bar max.)
  • Glycerine filling (over 40 mbar, under 250 mbar accuracy class 2.5)
  • Wetted parts with special coating
  • Open connection flanges according to EN/ANSI

...