Sistema de Analisis de gas para mediciones discontinuas

The BIOLYZER gas analyser was specially designed for discontinuous analysis and regular process monitoring of biogenous process gases such as biogas, sewage gas and landfill gas.
  • Detalles de Productos
  • Pregunta sobre este artículo

SISTEMA DE ANALISIS DE GAS PARA MEDICIONES DISCONTINUAS

alt
APLICACION MODELO TECNOLOGIA MARCA
Analítica BIOLYZER, BIOLYZER LT   Afriso
FUNCION CODIGO SECCION
Sistema de Analisis de gas para mediciones discontinuas. 10-5003 10

Gas analysis system BIOLYZER for discontinous measurement.

Application

The BIOLYZER gas analyser was specially designed for discontinuous analysis and regular process monitoring of biogenous process gases such as biogas, sewage gas and landfill gas. All important gas types such as methane, hydrogen sulphide, oxygen and carbon dioxide can be monitored..

. alt


Description

Complete measuring system for discontinuous, selective measurement and indication of up to four different gas components CH4, H2S, O2 and CO2. CH4 and CO2 are detected by means of infrared technology, O2 and H2S by means of electrochemical sensors. All components are integrated in a robust housing for wall mounting. The system feature a 4-digit LED display and status indicators for each measurement channel as well as a 4-line, back lit LCD display. The memory has a history function, all values can be displayed. Output 4–20 mA, fully adjustable alarm level switches and binary outputs for: Active, Error, Calibration, Alarm. A gas treatment unit with all important components (gas cooler, hose pump, fine filter, aerosol filter, rotameter with needle valve, anti-detonation device) is integrated in a robust, air-flushed housing. The system is supplied complete with wiring, capillary tubes, calibration and ready for installation

Technical specifications

Gas types/measuring ranges
CH4 0/100 % by vol. IR double beam
CO2 0/100 % by vol. IR double beam
O2 0/25 % by vol. electrochemical
H2S 0/5,000 ppm electrochemical

Measuring intervals can be programmed for all individual gas types. Manual measurement is possible at all times.

Gas treatment With anti-detonation device, protective filters, two pumps, two rotameters, needle valves, gas cooler with condensate trap and hose pump.
Display 4-digit LED display, status indicators for each channel, 4-line back lit LCD display, memory with history functions, all values can be displayed.
Communication RS 232, analogue output per gas type, output 4–20 mA, linearised, data memory/history
Operating temperature range Ambient: 5–40 °C
Supply voltage AC 85–264 V, 47–63 Hz
Dimensions W x H x D: Approx. 300 x 400 x 165 mm

BIOLYZER LT

BIOLYZER LT is intended for simple and cost-effective routine checks.
It is a BIOLYZER version, but it does not feature a gas cooler.
Neither does it have the load limitation for hydrogen sulphide measurement.
Therefore, the standard measuring range is 0 to 1,000 ppm H2S.

Options