( ... items )

FIELData Industrial

Ud. está en: Inicio » Productos » Catálogo de Productos » ANALÍTICA » Sistemas-Analítica »

Sistemas de tratamiento de gas MGK 744

Compact, portable and stationary gas treatment system in 1/2 19“ housing for gas analysis systems which withdraws a gas sample for the analysis process.
  • Detalles de Productos
  • Pregunta sobre este artículo

SISTEMA DE TRATAMIENTO DE GAS MGK 744

alt
APLICACION MODELO TECNOLOGIA MARCA
Analítica MGK 744   Afriso
FUNCION CODIGO SECCION
Sistemas de tratamiento de gas. 10-5002 10

Gas treatment system MGK 744.

Compact, portable and stationary gas treatment system in 1/2 19“ housing for gas analysis systems which withdraws a gas sample for the analysis process. Especially for longterm or continuous measurements and measurements involving pollution and/or condensate. Crucial for accurate and reproduc-ible measuring results.

. alt


Description

The unit consists of a half 19“ rack unit with permanently installed Peltier gas cooler which cools the gas to be measured to a temperature of +5 °C, irrespective of the withdrawal temperature or the ambient temperature. With hose pump for automatic condensate removal, gas pump, dust particle filter and flow meter with needle valve. The gas treatment system is equipped with a status detection unit to show the operational state of the cooler and also an additional master switch for the gas pump.

Gas cooler Peltier gas cooler for cooling the gas to +5 °C.
Gas filter Fine dust filter
Gas flow Flow setting using a rotameter and needle valve
Gas transport Gas pump
Condensate transport Condensate removal by a hose pump

The following options are available:

  • • 3/2-way solenoid valve (operation via switch on the front or via digital input)
  • • Portable housing 1/2 19", 3HU



Technical specifications

Gas output dew point: +5 °C
Gas input Max. 40 °C dew point, max. 80 °C gas temperature at 50l/h and 20 °C ambient temperature
Ready to operate After approx. 15 min.

Gas flow and filtering

  • 60 l/h at 200 mbar
  • Fine dust filter with glass fibre filter 2 μm


Status indication of gas cooler via LED at the front Temperature OK, cooling active, fault
Connection Capillary tube: 4 x 1 mm, clamping ring connection
Wetted parts Duran glass, PA, PC, Viton
Supply voltage AC 230 V/50 Hz, 60 W

Operating temperature range
Ambient: +5 °C/+40 °C
Storage: -15 °C/+55 °C

Protection: IP 20 (EN 60529)
Dimensions and weight Wx H x D: 42 DU x 3 HU x 290 mm approx 4.5 kg
 

alt

 








Suscripción a Newsletter

Nombre
E-mail *
Empresa
 



Tres Medios Web Hosting