Transmisor de Luminosidad - Aplicaciones de alta precisión linea

The TWN-LUX incorporates a silicon photodiode light sensor, in a hermetical sealed case, especially designed for high precision linear applications.
  • Detalles de Productos
  • Pregunta sobre este artículo

Aplicaciones de alta precisión lineal

alt
APLICACION MODELO TECNOLOGIA MARCA
Analítica - Instrumentos TWN-LUX -- Intech
FUNCION CODIGO SECCION
Transmisor de Luminosidad 15-1005A 15

Description:


The TWN-LUX incorporates a silicon photodiode light sensor, in a hermetical sealed case, especially designed for high precision linear applications. The sensor has a flat glass window with a built in colour correction filter, giving an approximation to the spectral response in the human eye. As an aid in adjustment an LED is mounted next to the sensor, with a gradual turn on at approx. 30% FSO. 
. alt Ver o Bajar PDF con Información Técnica. PDF Guía de Instalación.

 
Ordering Information:

TWN-LUX

Standard Calibration: 0~1000lux Nominal.
  Special Calibration Ranges available from 0~1lux to 0~5000lux.

TWN-LUX Specifications:

 

Input   Adjustable from 1~1000lux Nominal.
    Turn Trimpot fully Clockwise = 0~10lux Nominal.
    Turn Trimpot fully Anticlockwise = 0~1000lux Nominal.
    (Note: Trimpot requires 25 turns to go from one end to the other.)
Output -Voltage 0~10Vdc.
    Output Impedance = 1kΩ.
    (Note: With a 12Vdc power supply output may only rise within approx 95% FSO.)
  -Current 4~20mA, 3 wire.
    Maximum Load = 300Ω @ 12Vdc.
    Maximum Load = 900Ω @ 24Vdc.
Power Supply   12~24Vdc.
Current Draw -Voltage Output 20mA @ 24Vdc P/S with 10Vdc out.
  -Current Output 40mA @ 24Vdc P/S with 20mA out.
Operating Temperature   0~60C.
Storage Temperature   -20~80C.
Operating Humidity   5~85%RH Max. Non-Condensing.


 








Suscripción a Newsletter