( ... items )

FIELData Industrial

Ud. está en: Inicio » Productos » Catálogo de Productos » ANALÍTICA » Instrumentos »

Sonda de Oxígeno Oxystem 300 y Oxystem 500

For monitoring combustion and production processes as well as storage facilities, storage containers which require the oxygen concentration to be measured and/or controlled.
  • Detalles de Productos
  • Pregunta sobre este artículo

SONDA DE OXIGENO OXYSTEM 300 Y OXYSTEM 500

alt
APLICACION MODELO TECNOLOGIA MARCA
Analítica Oxystem 300, Oxystem 500   Afriso
FUNCION CODIGO SECCION
Sonda de Oxígeno. 10-4007 10

Oxygen probe Oxystem
Oxystem 300/Compact


This compact electronic oxygen measuring probe is designed for stationary installation. It consists of a 300 mm long zirconium dioxide measuring probe with an adjustable screw fitting and control electronics. Measuring range: 0.3 to 24.6 % O2 by volume Output: 0–10 V, alternative 4–20 mA.

.

. alt

 


Oxygen probe Oxystem
Oxystem 500/Wall Mounting


Similar to Oxystem 300/Compact, but with electronics in wall mounting housing. Control electronics and zirconium dioxide probe are connected by a special 2 m long cable. Flue gas temperature up to 450 °C.

. alt

 
Application

For monitoring combustion and production processes as well as storage facilities, storage containers which require the oxygen concentration to be measured and/or controlled. The unit provides inline oxygen measurement without gas treatment. A reliable dynamic zirconium dioxide O2 probe is used to generate the measured values. The advantages of the device result from the operating principle of the O2 probe. The probe is calibrated in atmospheric air. No reference gases are required. Due to the small compact design, the probe can be easily installed in the flue gas pipe. The probe provides fast and accurate measuring results. Oxystem 300/Compact is suitable for flue gas temperatures of up to 300 °C.

Features
 

  • In situ measurement directly in the gas duct
  • Compact design
  • Error-proof oxygen sensor
  • No gas treatment required
  • No test gas for calibration required


Technical specifications

Measuring range 0.3/24.6 % O2 by volume, corresponding to: 0.12 V to 10 V
Accuracy of measurement ±0.1 % O2 by vol.

Operating temperature range
Medium: Type 300 max. 300 °C Type 500 max. 450 °C
Ambient: 0/+50 °C

Sensor operating temperature 700 °C
Probe pipe (V2A) Ø 25 mm, L = 380 mm

Supply voltage One of the following:
AC 230 V, 10 VA
AC 110 V, 10 VA

Warming up time 5 minutes
Analogue output 0–10 V

Housing
Type 300: Impact resistant plastic (ABS) W x H x D: 104 x 170 x 65 mm
Type 500: Sheet steel, lacquered W x H x D: 165 x 160 x 90 mm

Protection IP 40 (EN 60529)
Weight 2 kg








Suscripción a Newsletter

Nombre
E-mail *
Empresa
 



Tres Medios Web Hosting