This NDIR unit provides continuous operation and can selectively measure and display the concentrations of up to four different gas components.
  • Detalles de Productos
  • Pregunta sobre este artículo

ANALIZADORES DE GAS INFRARROJO

alt
APLICACION MODELO TECNOLOGIA MARCA
Analítica IR Analyser   Afriso
FUNCION CODIGO SECCION
Analizadores de gas infrarrojo. 10-2003 10

Infrared gas analysers.

This NDIR unit provides continuous operation and can selectively measure and display the concentrations of up to four different gas components. The NDIR function principle is based on the absorption of infrared radiation by heteronuclear molecule gases with several atoms. Optimum sensitivity and high selectivity with regard to other components in the measurement gas are achieved by means of opto-pneumatic radiation receivers which are optimised for the application. Due to a built-in thermostat, even extremely small measuring ranges can be covered. An optional electro-chemical sensor makes it possible to additionally measure the oxygen concentration. Measuring range for oxygen up to 25 % by vol.

. alt

Application:

  • Room air control (CO, CO2, coolants)
  • Monitoring of activated carbon filters (CO, CO2)
  • Monitoring of inertness (CO2, O2)
  • Monitoring of biological processes (CO2, O2)
  • Measurement of landfill gases (CH4, CO2)
  • Monitoring of cold stores (O2, coolants)
  • Optimisation of heating systems (CO, O2)


Type-tested according to German directives (TA-Luft and BlmSchV 13 and 17)
For the following components:
0/250 mg CO
0/500 mg SO2
0/400 mg NO
0/10/25 O2 % by volume

A pressure-proof capsule version allows for use in Ex area, zones 1 and 2. The spectrum of measured components and combinations is growing constantly. An AFRISO expert will be pleased to answer any questions you have concerning your application. The conventional method with test gas can be used for calibration.

If the integrated calibration unit is used, test gas cylinders are not required. In addition, the system can be equipped with a pneumatic unit. It is also available in a housing for wall mounting.

Technical specifications

Supply voltage: AC 230 V
Gas throughput: 20/100 l/h
Analogue output: 4–20 mA
Interface: RS 232 C/V.24
Display 4-digit, backlit LCD display
Setup time: 15 s
Warming up time: 30 min.
Weight: approx. 10 kg
Design: 19" rack mounting or wall mounting

Measuring range (selection) smallest measuring ranges

CO 0 to 200 ppm
CO2 0 to 100 ppm
CH4 0 to 500 ppm
SO2 0 to 1000 ppm
C3H8 0 to 100 ppm
C6H14 0 to 500 ppm
NO 0 to 1000 ppm
N2O 0 to 100 ppm
Frigen 11 0 to 500 ppm
Frigen 12 0 to 100 ppm
Frigen 13b 0 to 100 ppm
O2 0 to 10/25 Vol.-%

Please enquire for other components or different versions of the system.